Doug,
Don't worry about solder alloys, they are capable, check with any serious paste supplier. The question is: are the components, actives mainly, able to take this heat? J-STD-020 specifies 245C as max temp for the bigger ICs.
Good luck,
Ioan Tempea, ing.
t : 450-967-7100 ext : 244
[log in to unmask]
www.digico.cc
P N'imprimer que si nécessaire - Print only if you must
-----Message d'origine-----
De : Douglas Erb [mailto:[log in to unmask]]
Envoyé : 23 mars 2009 11:59
À : [log in to unmask]
Objet : [TN] Low temp RoHS solder paste
In Asia, many CEMs are successfully applying components using RoHS
compliant solder pastes at 250C max temps in their ovens; so I've been
told by my colleagues in Japan. They do not have sourcing info on the
paste suppliers, however. Is anyone out there familiar with the
practice and if, indeed, there are new solder alloys that are capable of
achieving Class 3 wetting integrity at 250C?
Doug Erb,
Senior FAE
Hirose Electric USA
Industrial Segment
Office direct: (949) 218-3445
Fax direct: (949) 218-3425
Mobile: (949) 463-8447
Main office: (805) 522-7958
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|