Lee,

When you say "Evidently" that you have done cro




Lee,



When you say "Evidently" that you have done cross sectioning and see

that the cracks are only in the Ni and Au and not in the Cu?  Since you

said "There was no evidence of a lack of bonding between the copper and

the ENIG finish" that implies to me that you did cross section but since

I wasn't sure I thought I'd ask.



Regards,

George

George M. Wenger

Andrew Wireless Solutions

Senior Principal FMA/Reliability Engineer

40 Technology Drive, Warren, NJ 07059

(908) 546-4531 (Office) (732) 309-8964 (cell)

[log in to unmask]



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory

Sent: Wednesday, February 11, 2009 1:42 PM

To: [log in to unmask]

Subject: Re: [TN] CRACKED ENIG PADS



Hi Lee!



Have your pictures posted. They are here:



http://stevezeva.homestead.com/files/THROUGH_HOLE_CRACKS-1.jpg



http://stevezeva.homestead.com/files/THROUGH_HOLE_CRACKS-2.jpg



I have to let those that know more about plating than I do answer this

one...



Steve 



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Lee Whiteman

Sent: Wednesday, February 11, 2009 12:20 PM

To: [log in to unmask]

Subject: [TN] CRACKED ENIG PADS



I have asked Steve to put up a pair of pictures I received. They are of

cracks within the ENIG finish of a PWB. I know that the board failed,

based on IPC-6011 and IPC-6012.



My question is what would cause the cracking? Evidently, it is in the

Nickel layer and the copper layer was not compromised. There was no

evidence of a lack of bonding between the copper and the ENIG finish.

These boards are fresh from the supplier.



Just curious...



Thanks in advance.



Lee Whiteman, PMP

Senior Member Engineering Staff

L-3 Communications East

Telephone: (856) 338-3508

FAX: (856) 338-2906

E-Mail: [log in to unmask]

 



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:

http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

-----------------------------------------------------



------------------------------------------------------------------------------------------------

This message is for the designated recipient only and may

contain privileged, proprietary, or otherwise private information.  

If you have received it in error, please notify the sender

immediately and delete the original.  Any unauthorized use of

this email is prohibited.

------------------------------------------------------------------------------------------------

[mf2]



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2