Dear Technetters and Designers,
 
A question to resolve apparent conflict between the above IPCs.
 
As an example, take a 14 layer (4R+6F+4R) flex-rigid design 1.8mm thick
with polyimide/glass laminates and pre-preg used in rigid portions.
 
From IPC-2223A Table 4-2 Subnote (1) I would assume as <10% Low Tg
Laminate, the example would qualify as a Type 4(1), therefore requiring
Minimum Average Copper Thickness of 25um [984uim]. There is no Class
1,2,3 distinction.
 
But, IPC-6013B Table 1-1 Hole Plating for Type 4 > 6 layers Min.Ave
Copper for Class 3 calls for 35um [0.00138in]. This conflicts with
IPC-2223A Table 4-2 for a Type 4(1) Flex-rigid PCB and IPC-6013B Table
1-1 does not make distinction for amount of Low Tg material in build.
 
Could you help in understanding if I am missing something? Which should
be taken as "bottom line" - the design standard IPC-2223A or the
Qualification and Performance spec IPC-6013B for a high-rel application?
 
Thanks for your advice in advance.
 
Phil.
 
 

********************************************************************
This email and any attachments are confidential to the intended recipient and may also be privileged. If you are not the intended recipient please delete it from your system and notify the sender. You should not copy it or use it for any purpose nor disclose or distribute its contents to any other person. 

MBDA UK Limited, a company registered in England and Wales, registration number 3144919 whose registered office is at Six Hills Way, Stevenage, Hertfordshire, SG1 2DA, England.
********************************************************************


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2