Hi,

Thank you for your quick reply!
I really don't want to use only the top heaters. One of my engineers insists
that the bottom heaters are not necessary. I know about the warping problem
and the possible cracks. But he measure only 5 C differences between both
sides. It is over 2 mm board populated with BGA components?


2009/1/6 Steve Gregory <[log in to unmask]>

> Hi Eli!
>
> I have a couple of questions; you say that you measure *almost* the same
> temperature on the top and bottom, how much is almost?
>
> My second question is; why would you only want to use the topside
> heaters?
>
> Steve
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Eli Sarig
> Sent: Tuesday, January 06, 2009 1:16 PM
> To: [log in to unmask]
> Subject: [TN] Question about bottom heaters of reflow oven
>
> Hi all,
>
> My question is related to the necessity of down heaters in the reflow
> oven.
> When we solder double sided boards, we *can* create a suitable reflow
> profile using *only* the top heaters of the oven.
> In that case, the bottom heaters remain at room temperature. We measure
> almost the same temperature on top and bottom of the board.
> Are there any limitations or problems that might happen using this kind
> of process?
>
> Thanks,
>
> Eli.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
> archives of previous posts at: http://listserv.ipc.org/archives Please
> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2