Hi Pradeep,
How do you define "maximum allowable resin recession of 10%"--10% of what?
Resin recession is much more design related [Cu plating thickness, distance between innerlayer lands, resin content, degree of resin cure] than processing related.
You can get that by plating thick Cu, keeping all lands [functional and non-functional] and laminate as resin-poor as possible,
Werner
-----Original Message-----
From: mp3 <[log in to unmask]>
To: [log in to unmask]
Sent: Fri, 16 Jan 2009 12:55 am
Subject: [TN] Resin Recession
Dear all,
As per IPC 600G 3.1.9, resin recession after thermal stress is not considered as
a defect for all classes of boards unless specified in the procurement document.
We have a high reliability customer who requires 3 times thermal stress ( 3
cycles of solder dip for 10 secs at 288 deg C) to be done, with a maximum
allowable resin recession of 10%. We find this to be extremely stiff . Can
anybody provide us a feedback on this and any suggestions to achieve this.
Rgds,
Pradeep.M
Assistant General Manager
Micropack Limited
Plot#16, Jigani Industrial Area,
Anekal Taluk, Bangalore - 562 106
India
Tel : 91 80 27825223 / 27825224
Fax : 91 80 27825225
email : [log in to unmask]
visit us @ www.micro-pack.com
-------------------------------
Micropack Ltd, Bangalore, India
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|