It is not the standard for .040" materials.  


James Hofer
General Manager
Accurate Circuit Engineering (ACE)
3019 S. Kilson Dr.
Santa Ana CA 92707-4202
[log in to unmask]
(714) 546-2162 wk
(714) 473-6127 cell

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Fox, Ian
Sent: Friday, January 09, 2009 5:54 AM
To: [log in to unmask]
Subject: Re: [TN] PCB thickness tolerance question...Am I losing it?

I think that's standard double sided rigid thickness tolerance for .040"
material

Regards
Ian Fox
Lead Materials and Process Engineer
Aero Engine Controls
A Rolls-Royce plc and Goodrich Corporation Joint Venture
 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kevin Glidden
Sent: 09 January 2009 13:42
To: [log in to unmask]
Subject: [TN] PCB thickness tolerance question...Am I losing it?

We have a small PCB that is less than 2" x 2" square.  Material is
IPC-4101/21 FR4 with 2 oz copper.  2 layers.  Finish is Tin-Lead HASL.
 
Total thickness is specified as .040" +/- .005", and the supplier is
requesting increase to .040" +/- .006".  Is it me, or is +/- .006"
excessive for a 2 layer .040" thick PCB?  I was always taught a "rule of
thumb" that the PCB thickness tolerance is +/- 10% of the specified
nominal thickness.
Is this a bad "rule of thumb"?  Even +/- .005" is 12.5%!  Is this a sign
of a problem with the supplier's process?
 
Thanks!
 
Kevin Glidden
Manufacturing Engineer
Luminescent Systems Inc.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

------------------------------------------------------------------------
--
Rolls-Royce Goodrich Engine Control Systems Limited.
Registered Office: Moor Lane, PO Box 31, Derby, DE24 8BJ.
Registered in England No. 06686268.
------------------------------------------------------------------------
--

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2