It looks like there could be something fishy in the intermetallic layer.
GA, can you tell me please what is the reading on the micron bars?

Regards,

Vladimir

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Thursday, January 15, 2009 8:05 AM
To: [log in to unmask]
Subject: Re: [TN] Possible cause on open

Mornin' Everbody!
 
Well, here in Tulsa, we're just like a lot of other people in the
country this morning, trying to stay warm. Right now we're sitting at
-10 C. with a wind chill of -15 C. It's supposed to be colder
tomorrow...
 
GA, I have your pictures posted now. They're at:
 
http://stevezeva.homestead.com/files/Fracture1.jpg
 
http://stevezeva.homestead.com/files/Fracture2.jpg
 
Hopefully someone can give you some ideas...
 
Steve
 

________________________________

From: Tan Geok Ang [mailto:[log in to unmask]] 
Sent: Wednesday, January 14, 2009 7:27 PM
To: [log in to unmask]; Steve Gregory
Subject: Possible cause on open



Hi Steve,

            Please help to download these pictures TechNet, thanks.

     

 

 

Hi All experts,

            Testing (combine test of 16G at 85 oC) was performed on
evaluation boards with under-filled BGAs. Open issue (cracks) was
detected only at some corners of the BGA (35x35mm with 1156 balls) after
the test. Lead-free process and PCB with ENIG surface finish. Peak
temperature is 248 oC with a 65 sec above 217 oC. 

FYI, the service lab has not come out a report.

            What are the possible causes? (CET mismatches, Lead-free
alloy related, material, processes)

 

            Thank you in advance.

 

Regards

GA Tan

  


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2