The minimum requirement for the start of the bend away from the
component body (or lead weld, if present) is one lead diameter.  In
other words, the leads must exit the component body straight out a full
lead diameter before beginning the bend. However, that does not mean you
cannot use the part, as there are a number of options available. 
1. Form the leads in a pigtail.
2. Orient the component axis vertical to the PWB. (Also called a hairpin
configuration). This may require a bend in the bottom lead to provide a
standoff so the component body does not plug the PTH or interfere with
formation of a good SJ.
3. Form the leads down and inwards. This does preclude any portion of
the body resting on the PWB which may or may not be a good thing in
terms of heat dissipation.

In any of the above configurations, you are still required to meet the
one lead diameter minimum between the body and the start of the bend.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Jack Olson
Sent: Thursday, December 18, 2008 2:14 PM
To: [log in to unmask]
Subject: [TN] axial lead bend

We are trying to put a larger axial part in a smaller through-hole
footprint.
The body of the NEW part is ALMOST as long as the hole spacing.

Is there any requirement for how much room is needed for lead bend?
(IPC-A-610 doesn't address this, unless I missed it)

thanks,
Jack

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2