Assuming it is a wave soldering process, a Pealable Solder Mask placed
over the TH on the wave side could work.
Consult your PWB manufacturer  for dimensions and process compliance.
 
Mickey
 

  _____  

From: [log in to unmask] [mailto:[log in to unmask]] 
Sent: Friday, November 28, 2008 5:08 PM
To: TechNet E-Mail Forum; weiner, mickey
Subject: Re: [TN] Tenting of vias and spare PTH


Tenting the vias could inpact testability and reduces the ability to
clean. 
The safest solution is to use a batch cleaner with Kyzen or Envirogold
316 flux cleaner 5% with Di water. These saponifers reduce the surface
tension of water and are excellent cleaners. The boards must be cleaned
in the aqueous cleaner within ten minutes to remove the caustic soap.
Kyzen in Manchester NH makes this cleaner and sells the Kyzen
saponifier.  The use of the batch cleaner allows you to use the existing
aqueous cleaner and not contaminate the cleaner with saponifers that
cloud the glass windows and require down time to descale the heaters of
the tank with the saponifier. 
John Goulet 
Sr Manufacturing Engineer
 

	-------------- Original message -------------- 
	From: "weiner, mickey" <[log in to unmask]> 
	
	> Bogert 
	> What is the final finish of this board 
	> 
	> 
	> Mickey 
	> 
	> -----Original Message----- 
	> From: TechNet [mailto:[log in to unmask]] On Behalf Of - bogert 
	> Sent: Thursday, November 27, 2008 5:05 PM 
	> To: [log in to unmask] 
	> Subject: [TN] Tenting of vias and spare PTH 
	> 
	> We have an existing design PWA with socket mounted parts. The
design 
	> has vias under the sockets as well as PTH under the sockets
that were 
	> intended for use as spares to facilitate future design
changes. The 
	> sockets are of the open construction frame type (an H
configuration), or 
	> otherwise are body-less sockets. We are considering removing
all 
	> sockets and direct soldering the compo nents into the existing
PTH using 
	> ORL0 type flux. 
	> 
	> We are concerned about flux residue and other forms of
contamination 
	> such as from the PWB manufacturing process and the PWA
assembly process 
	> getting into the open via and spare PTH and not being removed
by the 
	> in-line cleaning system. 
	> 
	> We are considering having the vias and spare PTH tented in
some fashion. 
	> We need to retain use of the tented spare PTH for future use
if needed. 
	> What method do folks recommend to tent vias on equipment that
was 
	> already designed with un-tented vias and spare PTH? 
	> 
	> On a go forward basis, we are considering mandating that if
vias are 
	> used under components, they must be tented and we will not
allow spare 
	> PTH under any component. Allowing spare PTH under open frome
or 
	> bodyless sockets was a dumb idea. 
	> 
	> ------------------------------------------------ --- 
	> Technet Mail List provided as a service by IPC using LISTSERV
15.0 To 
	> unsubscribe, send a message to [log in to unmask] with following
text in 
	> the BODY (NOT the subject field): SIGNOFF Technet To
temporarily halt or 
	> (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET 
	> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all
the 
	> posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the 
	> archives of previous posts at:
http://listserv.ipc.org/archives Please 
	> visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
	> additional information, or contact Keach Sasamori at
[log in to unmask] or 
	> 847-615-7100 ext.2815 
	> ----------------------------------------------------- 
	> 
	> 
	> 
	> 
	> CONFIDENTIALITY 
	> This e-mail message and any attachments thereto, is intended
only for use by the 
	> addressee(s) named herei n and may contain legally privileged
and/or confidential 
	> information. If you are not the intended recipient of this
e-mail message, you 
	> are hereby notified that any dissemination, distribution or
copying of this 
	> e-mail message, and any attachments thereto, is strictly
prohibited. If you 
	> have received this e-mail message in error, please immediately
notify the sender 
	> and permanently delete the original and any copies of this
email and any prints 
	> thereof. 
	> ABSENT AN EXPRESS STATEMENT TO THE CONTRARY HEREINABOVE, THIS
E-MAIL IS NOT 
	> INTENDED AS A SUBSTITUTE FOR A WRITING. Notwithstanding the
Uniform Electronic 
	> Transactions Act or the applicability of any other law of
similar substance and 
	> effect, absent an express statement to the contrary
hereinabove, this e-mail 
	> message its contents, and any attachments hereto are not
intended to represent 
	> an offer or acceptance to enter into a contract and are not
otherwise intended 
	> to bind the sender, Sanmina-SCI Corporation (or any of its
subsidiaries), or any 
	> other person or entity. 
	> 
	> --------------------------------------------------- 
	> Technet Mail List provided as a service by IPC using LISTSERV
15.0 
	> To unsubscribe, send a message to [log in to unmask] with
following text in 
	> the BODY (NOT the subject field): SIGNOFF Technet 
	> To temporarily halt or (re-start) delivery of Technet send
e-mail to 
	> [log in to unmask]: SET Technet NOMAIL or (MAIL) 
	> To receive ONE mailing per day of all the posts: send e-mail
to 
	> [log in to unmask]: SET Technet Digest 
	> Search the archives of previous posts at:
http://listserv.ipc.org/archives 
	> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
	> additional information, or contact Keach Sasamori at
[log in to unmask] or 
	> 847-615-7100 ext.2815 
	> ----------------------------------------------------- 


CONFIDENTIALITY
This e-mail message and any attachments thereto, is intended only for use by the addressee(s) named herein and may contain legally privileged and/or confidential information. If you are not the intended recipient of this e-mail message, you are hereby notified that any dissemination, distribution or copying of this e-mail message, and any attachments thereto, is strictly prohibited.  If you have received this e-mail message in error, please immediately notify the sender and permanently delete the original and any copies of this email and any prints thereof.
ABSENT AN EXPRESS STATEMENT TO THE CONTRARY HEREINABOVE, THIS E-MAIL IS NOT INTENDED AS A SUBSTITUTE FOR A WRITING.  Notwithstanding the Uniform Electronic Transactions Act or the applicability of any other law of similar substance and effect, absent an express statement to the contrary hereinabove, this e-mail message its contents, and any attachments hereto are not intended to represent an offer or acceptance to enter into a contract and are not otherwise intended to bind the sender, Sanmina-SCI Corporation (or any of its subsidiaries), or any other person or entity.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2