We did see exactly this (dewetting on PTH pads leaving black nickel exposed) 
on some batches of product from one supplier back in 2006.

XRF analysis showed that gold deposit was thin (borderline acceptable) and by 
microsection of failed joint that the underlying nickel surface topography was 
very rough, due to excessive mechanical abrasion of the copper prior to ENIG 
deposition. Theory was that peaks of the rough nickel were poking through 
thin gold especially at the edges of PTH pads.

We don't use this supplier anymore...

Hope this might help

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2