Hello Pete, 



Thank you for the information below.



BTW, did you do any test to improve wetting contact angle for the lead PTH 

connected with copper plane with thermal relief? At the lead free wave 

soldering process in our facility, the wetting contact angle exceed 90° 

and the surface appearance of the solder joint looks as follows. Any 

thoughts on this? Thanks a lot.

 

                              __

                             |    | <--------------- Component Lead

                             |    |

                            /     \

                          /        \  <-------------- Surface Appearance 

of Solder Joint

                        /           \

                      /              \

                     |                 | <------------ 90° wetting 

contact angle

     _________|__________|________  The surface of copper plane 





Best Regards

Charming Chan

PCBA Engineer











Pete Houwen <[log in to unmask]>

发件人: TechNet <[log in to unmask]>





2008-10-29 21:06

请答复 给 TechNet E-Mail Forum; 请答复 给 Pete Houwen

 

        收件人:        [log in to unmask]

        抄送: 

        主题:  Re: [TN] How to improve solder filling and wetting contact 

angles for thermal vias at wave soldering process.





We did some testing of design parameters when we switched to lead-free, 

and 

found that the lead-hole ratio is more critical.  We also found that top 

side 

pad size is irrelevant for hole fill, but large bottom side pads can 

adversly 

affect hole fill.  Using this chart, we are able to achieve 75% with 

regularity 

(and we do not have the best process controls in our plant):



Lead Range               Pad Size                Hole Size

.000-.017                0.05            0.026

.018-.022                0.06            0.035

.023-.027                0.07            0.04

.028-.032                0.07            0.046

.033-.042                0.08            0.052

.043-.052                0.09            0.062

.053-.063                0.1             0.073

.064-.076                0.11            0.086

.077-.086                0.12            0.096

.087-.106                0.14            0.116

.107-.115                0.15            0.125

(dimensions in inches)



standard plane connects are thermal relief, using (4) .008" spokes.



This testing was done only to establish design parameters, there are 

plenty of 

process parameters that will affect hole fill.  But if your design 

parameters 

aren't good, all the process tweaks in the world won't fix trhe problem.



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 

for additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815

-----------------------------------------------------









--------------------------------------------------------

ZTE Information Security Notice: The information contained in this mail is solely property of the sender's organization. This mail communication is confidential. Recipients named above are obligated to maintain secrecy and are not permitted to disclose the contents of this communication to others.

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the originator of the message. Any views expressed in this message are those of the individual sender.

This message has been scanned for viruses and Spam by ZTE Anti-Spam system.


ATOM RSS1 RSS2