This table seems very valuable.
Pete , can You add additional information?
Which board thicknesses are investigated?
Which finishes are investigated?
I attach the information of the SMTA-Paper, reporting some investigations on OSP-finish :
IMPROVING HOLE-FILL IN LEAD-FREE SOLDERING OF THICK PRINTED CIRCUIT BOARDS WITH OSP FINISH
Sanmina-SCI Corporation (LF2)
from SMTA Conference 2008, Orlando, Florida, August 17 -21, 2008
They told that they had a big rejection rate with OSP finish, where gap is less than 11,5 mils. This leads to different values to Your table?.
Sincerly
Michael Jeremias
Industrial Engineering (OPPI41)
Electronics Production
((( Defence Electronics
EADS Deutschland GmbH
89077 Ulm
Tel.: +49 (0) 7 31.3 92-5533
Fax: +49 (0) 7 31.3 92-73 15
E-Fax: +49 (0) 7 31.3 92-20 5533
mailto: [log in to unmask]
EADS Deutschland GmbH
Registered Office: Ottobrunn
District Court of Munich HRB 107 648
Chairman of the Supervisory Board: Dr. Thomas Enders
Managing Directors: Dr. Stefan Zoller (chairman), Michael Hecht
This E-mail and any attachment(s) to it are for the addressee's use only.
It is strictly confidential and may contain legally privileged information. No confidentiality or privilege is waived or lost by any mistransmission.
If you are not the intended addressee, then please delete it from your system and notify the sender immediateley. You are hereby notified that any use,
disclosure, copying or any action taken in reliance on it is strictly prohibited and may be unlawful. - Thank you.
-----Ursprüngliche Nachricht-----
Von: TechNet [mailto:[log in to unmask]] Im Auftrag von Pete Houwen
Gesendet: Mittwoch, 29. Oktober 2008 14:07
An: [log in to unmask]
Betreff: Re: [TN] How to improve solder filling and wetting contact angles for thermal vias at wave soldering process.
We did some testing of design parameters when we switched to lead-free, and found that the lead-hole ratio is more critical. We also found that top side pad size is irrelevant for hole fill, but large bottom side pads can adversly affect hole fill. Using this chart, we are able to achieve 75% with regularity (and we do not have the best process controls in our plant):
Lead Range Pad Size Hole Size
.000-.017 0.05 0.026
.018-.022 0.06 0.035
.023-.027 0.07 0.04
.028-.032 0.07 0.046
.033-.042 0.08 0.052
.043-.052 0.09 0.062
.053-.063 0.1 0.073
.064-.076 0.11 0.086
.077-.086 0.12 0.096
.087-.106 0.14 0.116
.107-.115 0.15 0.125
(dimensions in inches)
standard plane connects are thermal relief, using (4) .008" spokes.
This testing was done only to establish design parameters, there are plenty of process parameters that will affect hole fill. But if your design parameters aren't good, all the process tweaks in the world won't fix trhe problem.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|