DC Members:
I have designed a flex assembly that will be subject to gamma
radiation (25-50 kGy) for sterilization purposes. We need to know
the effects of this radiation on the materials; Active & passive
comps, polyimid flex, solder & joints, etc...
Can anyone point me in the right direction where I might begin to
find this information? Is there an overall document and
specification? Would I need to contact the manufacturer of each P/N
and request this information. I have done flight boards in which
each component had to be rad-hard, is this a similar situation?
Thanks in advance!
David Baldwin CID+
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------