How clean are your boards and components before soldering? You have to
qualify a whole process, not just a single component, such as a flux.
Brian
Chafin, Ken G. wrote:
> We are trying to qualify a no-clean flux to be used in our wave solder
> process.
>
> The flux in question is Indium #9942.
>
> After wave soldering our boards are conformal coated with polyurethane
> coating Conathane CE-1164.
>
> We have done some baking of a test sample at 70 degrees C and and have
> tested per IPC-TM-650 2.6.7.1--thermal shock test.
>
> This testing was done primarily to evaluate the adequacy of the adhesion
> of the conformal coating.
>
> We are interested in further evaluating this flux to determine if it
> contributes to corrosion development or other undesirable effects.
>
> We are considering "soaking" a sample in a chamber at 70 degrees C at
> 95% relative humidity for four or five days.
>
> I am interested in any recommendations for further
> testing--standards-related tests, nonstandards-related tests that may
> reveal undesirable properties in the flux, etc.
>
> Thanks
>
>
>
> Kenneth Chafin
> Quality Compliance Leader
>
> <file:///c:/signature/Email%20signature_files/image001.jpg>
> 1000 Technology Drive
> Pittsburgh, PA 15219-3120
> USA
> Telephone: +1-412-688.2400 Ext [Ext]
> Telefax: +1-412-688.2399
> www.ansaldo-sts.com <http://www.ansaldo-sts.com/>
>
>
>
> CONFIDENTIALITY
> This message is strictly confidential. Its content and use is restricted
> to the designated recipients. The use, copy, reproduction or transmittal
> by any process or means without prior written notice of the Author or
> Ansaldo STS / Union Switch & Signal Inc. office of the Legal Counsel is
> strictly prohibited. If you have received this message in a transmission
> error, please inform the sender immediately and destroy any copy, saved
> files or print you have erroneously made.
>
>
> PRIVACY:
> Meeting the needs and expectations of our Customers and Employees has
> always been our highest priority and that includes protecting their
> privacy in compliance with local, state and federal laws and in
> accordance to Ansaldo STS/Union Switch & Signal Inc. Privacy Code.
>
>
> ENVIRONMENTAL NOTE:
> IN SUPPORT OF OUR ENVIRONMENT, WE RECOMMEND NOT PRINTING EMAILS EXCEPT
> WHEN ABSOLUTELY NECESSARY
>
>
>
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|