We did some testing of design parameters when we switched to lead-free, and
found that the lead-hole ratio is more critical. We also found that top side
pad size is irrelevant for hole fill, but large bottom side pads can adversly
affect hole fill. Using this chart, we are able to achieve 75% with regularity
(and we do not have the best process controls in our plant):
Lead Range Pad Size Hole Size
.000-.017 0.05 0.026
.018-.022 0.06 0.035
.023-.027 0.07 0.04
.028-.032 0.07 0.046
.033-.042 0.08 0.052
.043-.052 0.09 0.062
.053-.063 0.1 0.073
.064-.076 0.11 0.086
.077-.086 0.12 0.096
.087-.106 0.14 0.116
.107-.115 0.15 0.125
(dimensions in inches)
standard plane connects are thermal relief, using (4) .008" spokes.
This testing was done only to establish design parameters, there are plenty of
process parameters that will affect hole fill. But if your design parameters
aren't good, all the process tweaks in the world won't fix trhe problem.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------