Hi Leo,
Elongation data for foil samples are useless [except for process control purposes], because the aspect ratios of foil samples make the determination of material ductilty by tensile testing impossible.
There exists a test method, ASTM E796 and IPC-TM-2.4.2.1, that gives the actual material ductility of metallic foils.
Werner
-----Original Message-----
From: Lin Leo <[log in to unmask]>
To: [log in to unmask]
Sent: Wed, 15 Oct 2008 6:45 am
Subject: [TN] Elongation for CCL & electroplating Cu
Hi,
My customer asked me: Which is better in elongation between CCL and
electroplating Cu(from PCB panel plating or pattern plating Cu)?
Where could I find the elongation data for CCL & electroplating Cu?
Best regards
Leo
______________________________________________________________________________________________________
付費才容量無上限?Yahoo!奇摩電子信箱2.0免費給你,信件永遠不必刪! http://tw.mg0.mail.yahoo.com/dc/landing
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-ma
il to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|