Hi Werner,



Do you know if the Solder on Cupper over polymer is going to be standard? It's reliability improvement and the cost reduction with high volume, it make it a good start up...



Best Regards



Reuven ROKAH

e mail: [log in to unmask]

Think green before printing this mail... Thanks



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier /*

Sent: Thursday, September 18, 2008 4:58 AM

To: [log in to unmask]

Subject: Re: [TN] Copper BGA balls



Hi Genny,

Why would you want to use Cu balls--they do not improve reliability, because the ball is too rigid and you wind up with 2 very thin solder joints. Now polymer balls covered in Cu and solder is another matter--they improve reliability.









Werner





-----Original Message-----

From: Genny Gibbard <[log in to unmask]>

To: [log in to unmask]

Sent: Wed, 17 Sep 2008 7:00 pm

Subject: [TN] Copper BGA balls

















Anyone have experience with components using a tinned copper ball

instead of a SAC alloy solder ball?

Have you ever X-rayed one?

We are seeing voiding that does not meet the IPC-7095B spec for incoming

inspection with a transmission x-ray.  However, we don't know if this is

a concern for this type of ball, or if this spec even applies to this

type of ball.  I don't think these are meant to collapse and mix with

the solder on the board, like a normal solder alloy ball might.



Once again, thanks in advance for sharing your knowledge.



Genny



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



















---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------


ATOM RSS1 RSS2