Hi Ted,

I believe you would be well served by testing the reliability of the PWB
for degradation of the copper and material due to the thermal excursions
associated with RoHS assembly and rework. This is typically done with a
thermal cycle evaluation of representative coupons design to enunciate
variations in reliability expressed as cycles to failure.


Sincerely,

Paul Reid

Program Coordinator

PWB Interconnect Solutions Inc.
235 Stafford Rd., West, Unit 103
Nepean, Ontario
Canada, K2H 9C1

613 596 4244 ext. 229
Skype paul_reid_pwb
[log in to unmask] <mailto:[log in to unmask]>
 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Klefisch, Ted J
Sent: Wednesday, September 10, 2008 11:36 AM
To: [log in to unmask]
Subject: [TN] testing RoHS-compliant boards

Hello TechNet:

I work for a medical OEM.  We will soon be producing lead-free
RoHS-compliant PCBAs.

I need to identify appropriate standard test methods for performance and
reliability of the new PCBAs made with RoHS-compliant materials.  Is
there a standard shock and vibration test we should perform?  What other
tests should we do?  Would IPC-9701A be appropriate?

I would appreciate your recommendations and comments.  

Thanks in advance for your help.

Ted Klefisch
Covidien
Hazelwood, MO

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2