Dwight Mattix <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Dwight Mattix <[log in to unmask]>
Date:
Mon, 11 Aug 2008 10:17:45 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (191 lines)
We going to see plating accept criteria published 
for stacked uvias on the next go round?  Looking 
forward to being standardized that so that it's 
not just this <ahem> "unreasonable man" talking with our suppliers.

At 07:59 AM 8/8/2008, Whittaker, Dewey (EHCOE) wrote:
>Bob,
>Thanks for the information. I am on those 
>Committees that deal with these issues. We have 
>many updates/fixes under way on IPC-A-600, 
>IPC-6012, IPC-6011, IPC-2221, as well as several 
>other coupon/test task groups. I will see what 
>we can do to incorporate what you have presented.
>My attempt at illuminism in this endeavor, just 
>like with Deweyisms, does not guarantee they'll see the light.
>Dewey
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Bob Willis
>Sent: Friday, August 08, 2008 5:05 AM
>To: [log in to unmask]
>Subject: Re: [TN] measurement and acceptance of microvias
>
>Like to see any feedback from anyone that has tried the blind via test I
>reported in IPC Review a few months back as a alternative or support to the
>information seen during sectioning or IST due to the recent debate
>
>I hope that the updates to IPC 600 cover via inspection in more detail.
>
>See link to IPC Review Paper www.bobwillis.co.uk/pdf/viatest.pdf
>
>
>Bob Willis
>2 Fourth Ave, Chelmsford, Essex, CM1 4HA England
>Tel: (44) 1245 351502
>Fax: (44) 1245 496123
>Mobile: 07860 775858
>
>www.ASKbobwillis.com
>
>New Bob Willis "Printed Board Inspection & Quality Control Workshop" 3rd
>September www.ASKbobwillis.com/PCBworkshop.pdf
>
>Book your place on Bob's "Step by Step Failure Analysis Workshop" 11th
>September  www.ASKbobwillis.com/faworkshops.pdf
>
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Gerald Gagnon
>Sent: 07 August 2008 19:14
>To: [log in to unmask]
>Subject: Re: [TN] measurement and acceptance of microvias
>
>Hi Paul,
>
>Can I have a copy of the Curtis Wright, Coretec and PWB Inc paper to take a
>look at?
>
>You state some interesting results.
>
>Gerry
>
> > Date: Thu, 7 Aug 2008 13:25:19 -0400> From: [log in to unmask]>
>Subject: Re: [TN] measurement and acceptance of microvias> To:
>[log in to unmask]> > Hi Louis,> > We do a lot of microvia reliability testing
>here at PWB Inc. We have tested .002" to .006" microvias; drilled, plasma
>etched (flex circuits) and laser ablated; with and without fill, stacked;
>staggered etc.> > An aspect ratio of 1:1 or less is easier to clean,
>metalize and electro-plate, and, therefore, produces more reliable
>microvias. Many companies are producing reliable microvias with higher
>aspect ratios. You just have to tweak the process using an objective
>measurement like reliability testing to rank methods, processes or
>procedures.> > The shape of the microvia is critical. Flask shaped and
>perpendicular side walls (with right angles at the base) microvias are
>usually less reliable. A "bowl" shape microvia is most reliable but this has
>less surface area at the base than a straight hole wall. Out gassing
>chemistries, surface tension, and the lack of solution movement all conspire
>to inhibit cleaning and plating in corners at the base of the microvia. It
>appears liquid can circulate better in a "bowl" shaped microvia than one
>with straight side walls. So I would say the hole diameter to base surface
>has an inverse relation to reliability until you get below some undefined
>minimum hole or base size. > > Aggressive desmear, desmear that makes the
>hole wall rough, is less reliable. At the same time, any debris on the
>internal pad will induce early failures. The presents of a smooth, slightly
>angled hole wall and a slight microetch in the internal pad is optimal.> >
>Metrology counts in evaluating microvias. Contrary to what you may have
>heard, you must have a slight microetch to evaluate the integrity of the
>microvia in a microsection.> > We feel that you must test microvias at 190°C
>to fail weak microvia within 500 thermal cycles. Tested at 150°C bad
>microvias, ones that will fail in assembly, will survive thousands of
>thermal cycles.> > There is an article available. A joint study was
>undertaken between Curtis Wright, Coretec and PWB Inc. It covers much of
>what I have described.> > Contact me off line for more on microvias.> > By
>the way, I refrain from using the terms target and capture pad. What does
>IPC-T_50 call the external and internal pads in a microvia structure? > >
>Sincerely,> > Paul Reid> > Program Coordinator> > PWB Interconnect Solutions
>Inc.> 235 Stafford Rd., West, Unit 103> Nepean, Ontario> Canada, K2H 9C1> >
>613 596 4244 ext. 229> Skype paul_reid_pwb> [log in to unmask]
><mailto:[log in to unmask]>> > > -----Original Message-----> From:
>TechNet [mailto:[log in to unmask]] On Behalf Of Louis Hart> Sent: Wednesday,
>August 06, 2008 5:12 PM> To: [log in to unmask]> Subject: [TN] measurement and
>acceptance of microvias> > TechNetters, I'm trying to plan a designed
>experiment for optimization of a laser drilling operation, for microvias. I
>need to identify a variable to measure..> > Is the ratio of the diameter of
>the exposed copper at the bottom of a microvia to the diameter of the
>microvia at the surface of the board a suitable measurement? (The jargon may
>be 'ratio of target land diameter to capture land diameter'.)> > What is the
>target value for this ratio? I'm assuming there is one such number - please
>correct me if I am wrong.> > Thanks for any comments or guidance.> > Louis>
> > Louis Hart> Compunetics> Monroeville, PA> USA>
>[log in to unmask]<mailto:[log in to unmask]>> 412-858-1272> > >
>---------------------------------------------------> Technet Mail List
>provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a
>message to [log in to unmask] with following text in the BODY (NOT the subject
>field): SIGNOFF Technet To temporarily halt or (re-start) delivery of
>Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To
>receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest Search the archives of previous posts
>at: http://listserv.ipc.org/archives Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information,
>or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815>
>-----------------------------------------------------> >
>---------------------------------------------------> Technet Mail List
>provided as a service by IPC using LISTSERV 15.0> To unsubscribe, send a
>message to [log in to unmask] with following text in> the BODY (NOT the
>subject field): SIGNOFF Technet> To temporarily halt or (re-start) delivery
>of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)> To
>receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest> Search the archives of previous posts
>at: http://listserv.ipc.org/archives> Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information,
>or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815>
>-----------------------------------------------------
>_________________________________________________________________
>Got Game? Win Prizes in the Windows Live Hotmail Mobile Summer Games Trivia
>Contest
>http://www.gowindowslive.com/summergames?ocid=TXT_TAGHM
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of 
>Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: 
>send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site 
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach 
>Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of 
>Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: 
>send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site 
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach 
>Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------