Techies

I thought I would share some info that, I feel, is relevant to this  
question.

Albeit some time ago, my company supplied a dip coating system to a  
major automotive electronics manufacturer who were using a silicone  
conformal coating.

So what, you might say?

Well, we found that, despite an 8 hour bake at around 80DegC, the  
residual/accumulated moisture "entrapped" into the assembly, was  
sufficient to kick-over the moisture sensitive coating.

So what? Well, this meant that the coating remaining in the dip tank -  
some 60 litres (15.85 gallons = US Term) - had to be disposed of every  
2 weeks (Fortnight = British term!)

3 issues:

1 = Environmental impact in the disposal of 60 litres of product every  
2 weeks.

2 = Cost impact of same

3 = How come the bake was not able to eliminate this problem?

So - I hope the new document might yield some recommendation as to the  
minimum baking time to avoid this phenomenon.

Thinks - maybe I need to spell that Fenomenon rather than  
phenomenon....? [thinks - I am somewhere framed on the walls of Mr  
Pauls....] (Dewey - that rhymes, sorry, rimes? Excuse me, Rymes?) Ah!  
What the heck.

Graham Naisbitt

On 28 Aug 2008, at 17:45, Joe Macko wrote:

> Denny,
>
> We have always treated FR4 PCBs as moistures sensitive and baked them
> out before reflow to be safe. Everyone has there own idea about bake  
> out
> time and temperature and most CMs do consider the PCB moisture
> sensitive. We bake for 5-6 hrs at 110 C. Boards are generally used
> within 2-weeks of bake out.
>
> Best Regards,
> -joe
>
>
>
> "This e-mail and any attachments are solely for the use of the  
> addressee and may contain L-3 proprietary information that may also  
> be defined as U.S. Government export controlled technical data. If  
> you are an unintended recipient of this e-mail, use, disclosure or  
> distribution of its content is prohibited. Please notify the sender  
> by return e-mail and immediately delete this message."
>
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Dennis Fritz
> Sent: Wednesday, August 27, 2008 7:10 AM
> To: [log in to unmask]
> Subject: Re: [TN] Moisture in PCB Assemblies
>
> Bill,
>
> There has been some speculation that with the higher assembly
> temperatures of lead-free, that PCBs should have a Moisture  
> Sensitivity
> Level - just like the components being mounted on them.? However, I
> don't think JEDEC will step up to the plate to adopt anything to do  
> with
> PCBs.? So, it would be the job of the IPC to do that.?
>
> With the upcoming IPC meeting in late September, Schaumburg,  
> Illionois,
> now would be a good time to debate the need for circuit board MSL
> levels. As pointed out, the group working on Storage and Handling will
> go a long way, but moisture absorbsion propensity is also a property  
> of
> the resin/glass composition of the board.?
>
> How about it TechNetters?
>
> Denny Fritz
> MacDermid, Inc.
>
>
> -----Original Message-----
> From: [log in to unmask]
> To: [log in to unmask]
> Sent: Tue, 26 Aug 2008 7:19 pm
> Subject: [TN] Moisture in PCB Assemblies
>
>
>
> Fellow TechNetters:? I was asked a question by a valued customer if
> there is any
> other references made to moisture in raw PCBs and populated assemblies
> other
> than the J-STD-033 and also the IPC rework standards.? I've looked in
> IPC
> Standards I have on file however I could not find any
> references/guidlelines at
> all.? Can anyone out there shed some light on this???
>
> I thank you folks in advance for your efforts on my behalf.
>
> Bill Black
> Medco
> Q.A. Manager
> Tel:? 631-667-9699
>
> E-Mail:? [log in to unmask]
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> -----Original Message-----
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask] 
> : SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask] 
> : SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>  for additional information, or contact Keach Sasamori at [log in to unmask] 
>  or 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2