Hi
The copper thickness requirement is the same but there is a minimum fill
requirement for blind and buried vias. The plating requirements is listed
in 6012B table 3-2, the fill requirement is stated in 3.6.2.16, beware
that for space and military avionics the requirements are tighter.
br
Grunde
Scott Westheimer <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
19.08.2008 09:51
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Scott Westheimer <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[TN] Via hole fill
Can someone be so kind as to direct me to the IPC specification that
covers filled via's. I am looking for the min average copper plating
thickness required. These are non-conductive filled via's.
Thanks in advance.Scott B. Westheimer5709 Clarks Fork DriveRaleigh, NC
[log in to unmask]: (919)713-0748Cell NC: (919)961-5364
_________________________________________________________________
Get ideas on sharing photos from people like you. Find new ways to share.
http://www.windowslive.com/explore/photogallery/posts?ocid=TXT_TAGLM_WL_Photo_Gallery_082008
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------