TECHNET Archives

August 2008

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Inge <[log in to unmask]>
Date:
Thu, 14 Aug 2008 10:54:11 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (178 lines)
mutual potentiality ?

Inge


----- Original Message ----- 
From: "Whittaker, Dewey (EHCOE)" <[log in to unmask]>
To: "TechNet E-Mail Forum" <[log in to unmask]>; "Inge" 
<[log in to unmask]>
Sent: Thursday, August 14, 2008 10:42 AM
Subject: RE: [TN] TG 130 or Tg 170 for ENIG


I see my humor is having a galvanizing affect on you.
Dewey

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: Thursday, August 14, 2008 10:38 AM
To: [log in to unmask]
Subject: Re: [TN] TG 130 or Tg 170 for ENIG

To a high degree better

Inge


----- Original Message ----- 
From: "John Burke" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, August 14, 2008 10:27 AM
Subject: Re: [TN] TG 130 or Tg 170 for ENIG


>I agree
>
>
>
> John Burke
>
> (408) 515 4992
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Douglas O. Pauls
> Sent: Thursday, August 14, 2008 9:23 AM
> To: [log in to unmask]
> Subject: Re: [TN] TG 130 or Tg 170 for ENIG
>
> I don't know if it is a "standard practice", but I would certainly
> recommend it.  You need the extra margin that the higher Tg gives.
>
> Doug Pauls
>
>
>
>
> Lenny Carter <[log in to unmask]>
> Sent by: TechNet <[log in to unmask]>
> 08/14/2008 11:19 AM
> Please respond to
> TechNet E-Mail Forum <[log in to unmask]>; Please respond to
> Lenny Carter <[log in to unmask]>
>
>
> To
> [log in to unmask]
> cc
>
> Subject
> [TN] TG 130 or Tg 170 for ENIG
>
>
>
>
>
>
> Hey technetters- We adopted the ENIG finish for our RoHS compliant
parts 2
> years ago.  We recently had discussions with our primary pcb vendor
and
> they
> recommended we switch to a Tg170 FR4 material for our pcbs instead of
our
> standard Tg130 we have been using for years.
> This recommendation was made because of the higher reflow temperatures
> necessary for the lead free process.
>
> Is this standard practice?  we are a little hesitant to make the
switch as
> it would mean an approximate 5%price increase on all our pcbs.
>
> Any input is appreciated.
>
> thanks, Lenny Carter  ERG, Inc.   www.ergpower.com
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at
[log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at
[log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at
[log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2