The answer is clear. Cleaning should be carried out AS SOON AS POSSIBLE
after soldering. The longer the time gap, the harder the residues become
and the more difficult they are to remove. The ideal is to start the
cleaning as soon as you can comfortably hold the assemblies. This does
not mean that you may not be able to clean them the following day, but
you may have difficulties.
The old 1 h limit of the MIL specs is a legacy from the days when we
soldered with an RMA flux to MIL-F-13949 (number if my memory is OK) and
cleaned with a CFC-113 blend. We have moved beyond these days. If you
use a WS flux, you may find the solder is horribly matt if you wait as
long as one hour!
So the answer is ASAP but do whatever gives you provably good results,
whether it be 1 minute, 1 hour or 1 day. NEVER rely on specifications
for this kind of thing because the guys who wrote them had no idea which
flux YOU would be using, which soldering process YOU would use, which
cleaning product YOU would use or which equipment YOU would use. Only
YOU can prove that your process is good, by scientific qualification.
You are really asking how long a piece of string is.
Brian
- bogert wrote:
> July 23, 2008
>
> J-STD-001 is silent on how long a time span is acceptable between wave
> or reflow soldering and post cleaning for instances where cleaning is
> mandated because organic Type M or H flux was used.
>
> I believe the historical soldering specs MIL-STD-2000 and MIl-STD-454
> requirement 5 mandated no more than one hour between cleaning and
> solddering.
>
> Is there a technically necessary maximum limit and if so is there data
> to support it? If there is a technical supported limit why should we
> mandate it in J-STD-001?
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|