All,

 

IPC-6012A with amendment 1, section 3.5.1, Conductor Width and Thickness
states, "When not specified on the master drawing the minimum conductor
width shall be  80% of the conductor pattern supplied in the procurement
documentation".  The PCB suppliers interpret this to mean that BGA pads
for example can be 80% of the pad diameter specified in the procurement
documentation, which is the GERBER files unless specified otherwise and
still be acceptable per IPC-6012.

 

I am interested to hear how other users handle allowable reductions in
BGA pad size from that specified in the procurement documentation.
thanks

 

Best Regards,

-joe

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2