Hi Werner,

 

That is obviously your choice but I'd prefer to stick with mine :-)

 

I still think that BP and BF are two completely different phenomena and
the fact that BF occurs not just on ENIG boards, but with almost all
other finishes (of cause only for Pb-free solders) makes me think that
I'm right. 

 

Be careful with using/interpreting EDS for fracture surfaces. It's NOT
that straight forward.

 

Regards,

 

Vladimir

 

________________________________

From: [log in to unmask] [mailto:[log in to unmask]] 
Sent: Friday, June 20, 2008 4:05 AM
To: Igoshev, Vladimir; [log in to unmask]
Subject: Re: [TN] [LF] [TN] SN100 for Reflow Application

 

Hi Vladimir,
For BP I am really only concerned about the surface, so EDS is
fine--after all it is the interface surface that is weak. 
Cavitation (as a ME that word bothers me because cavitation is what a
propeller does in water) is a sign of the P notdoing its job.
So I stand by my definition.



Werner Engelmaier
Future workshops:
Solder Joint Reliability: Parts 1 through 4, July 17/18, Thal,
Switzerland
Pb-Free Soldering Processes-Survival, Quality, Reliability, August 18,
Orlando
Reliability Issues with Lead-Free Soldering Processes, September 22,
Schaumburg
Failure Mode and Root Cause Analyses Reliability (Fatigue, Brittle
Fracture, ENIG), September 22, Schaumburg



**************
Gas prices getting you down? Search AOL Autos for fuel-efficient used
cars.
(http://autos.aol.com/used?ncid=aolaut00050000000007)


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2