It depends... how good is your ENIG?
Sorry, it is Friday...couldn't resist...jk

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joe Macko
Sent: May 23, 2008 1:41 PM
To: [log in to unmask]
Subject: [TN] Methodology for determining the # of reworks ENIG finished
solder lands for leaded components can withstand

Techs,

 

I am looking for some help / guidance on how to analytically determine
the number of times the same leaded component can be replaced on a ENIG
finished board before the solder lands located on the PCB have been
degraded beyond their capability to provide a solderable class 3 surface
(.e., how many times can the ENIG finished solder lands with stand a
rework/component remove & replace).  I suspect the dissolution rates of
nickel and copper come into play however I am not sure how to approach
this issue and suspect there are some relatively straightforward
formulas out there to accomplish this task. Everyone has a different
idea and there are numerous rules of thumb discussed but I would like to
try something more analytical (without having to use a supercomputer).
Thanks again and everyone enjoy the long weekend.

 

Best Regards,

-joe

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2