 Vertrel was developed by DuPont as a "Green" replacement for cleaning solvent. We performed some tests on it and received very good results (compare to Abzol), and it is also been approved by some Aerospace companies.

It as Zero ozone depletion potential

Excellent toxicity profile

Design for electronics - high material compatibility



Regards,



Dr. Gil Zilber

Technologist, Elta system Ltd.

Tel. +972-8-8577240

Mobile +972-54-4983222

http://www.iai.co.il/site/en/iai.asp?pi=17887

 







-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Charlie Pitarys

Sent: Thursday, May 22, 2008 8:59 AM

To: [log in to unmask]

Subject: Re: [TN] Are these substances OK for use in electronics



Combined ingredients in the can togther you have a non haz/non flammable mixture. the specific msds will comfirm that. The Nitromethane is probably the propellant media.

They are safe for electronics and have been in use for many years.

Are they effective cleaners on your assemblies should be the real question. They are very much a niche cleaner and efficacy against certain no clean formulas should be tested first. 

For water soluble /OA fluxes DO NOT USE !! The results will be a horrible hard white residue mess.

 

Plastics such as acrylics and other polycarb blends used for switch covers etc. should be avoided.



________________________________



From: TechNet on behalf of Ioan Tempea

Sent: Wed 5/21/2008 12:32 PM

To: [log in to unmask]

Subject: Re: [TN] Are these substances OK for use in electronics







Vertrel MS-755 and MS-780 from Miller Stephenson.







Thanks,







Ioan







________________________________



De : [log in to unmask] [mailto:[log in to unmask]]

Envoyé : May 21, 2008 12:26 PM

À : TechNet E-Mail Forum; Ioan Tempea

Objet : Re: [TN] Are these substances OK for use in electronics









Ioan,

What is the actual name of the product?  I would expect the fluoronated materials to be global warmers and the methanol and nitromethane go boom around flame.  



Doug Pauls









Ioan Tempea <[log in to unmask]>

Sent by: TechNet <[log in to unmask]>



05/21/2008 11:04 AM



Please respond to

TechNet E-Mail Forum <[log in to unmask]>; Please respond to Ioan Tempea <[log in to unmask]>



To



[log in to unmask]



cc







Subject



[TN] Are these substances OK for use in electronics





















Dear Technos,







I've got one for the chemists: a customer of ours requests us to clean their boards with 2 spray canned products. Here's the stuff that's inside of them:



1,1,1,2,3,4,4,5,5,5-Decafluoropentane



Trans,1,2-Dichloroethylene



Methanol



Nitromethane



1,1,1,2-Tetrafluoroethane







Are they safe for the product? What about the production personnel and the environment?







Thanks,







Ioan





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------







---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------



 The information contained in this communication is proprietary to Israel Aerospace Industries Ltd., ELTA Systems Ltd. 

and/or third parties, may contain classified or privileged information, and is intended only for 

the use of the intended addressee thereof. If you are not the intended addressee, please be aware 

that any use, disclosure, distribution and/or copying of this communication is strictly prohibited.

If you receive this communication in error, please notify the sender immediately and delete it from 

your computer. Thank you. 





This message is processed by the PrivaWall Email Security Server. 




---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------