I have solder paste calculator for stencil release. This may help you.
Contact me off line and I will send to you. 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Gumpert, Ben
Sent: Tuesday, May 20, 2008 12:44 PM
To: [log in to unmask]
Subject: Re: [TN] Average paste volume estimate

An easy way is to make a bunch of assumptions...

2" x 2" board
5 mil stencil
10% of board area is pasted
Paste is 50% metal
SnPb solder = 137.7	g/in^3 

In this case you would have .1377g of SnPb on a 2" square board (Which
ignores the fact that you asked for the amount of paste, not
solder)

This will only be close to accurate if you know some of the actual
values assumed above, stencil thickness and paste coverage area probably
having the highest impact.

Ben


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dan Mathews
Sent: Tuesday, May 20, 2008 12:10 PM
To: [log in to unmask]
Subject: [TN] Average paste volume estimate

 Does anyone have an easy way to estimate how much paste is applied to a
smt pcb? I understand it varies on 

squeegee pressure, stencil thickness, and pitch of the components but I
was looking for an average. I would

assume that somewhere out there someone can estimate that "2 grams of
paste is used on a 2" x 2" smt pcb". 

 

 I will then use this information to determine how much lead is used on
non-RoHS products due to solder paste 

issues and not non-compliant components. 

 

Thank You in Advance,

Dan

 

Dan Mathews C.I.D.+

Engineering Support Supervisor

B&B Electronics

Ottawa, IL USA 61350

Phone: 815-433-5100 ext 217

Fax: 815-434-8831 (direct to my desk)

URL: http://www.bb-elec.com <http://www.bb-elec.com/> 

 

 

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2