Hi Leland!

Do you use any sheilded wire on any of your products? Could be coming
from wire stripping?

Steve 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Leland Woodall
Sent: Tuesday, May 13, 2008 8:47 AM
To: [log in to unmask]
Subject: [TN] Stainless Steel Contamination Question
Importance: High

Hi Everyone,

 

We've had a problem lately with fine strands of stainless steel wire
being found on top of some of our .5 mm pitch ICs.  This has caused both
internal and external issues, and we've yet to identify the source.

 

It's definitely formed wire, with a thickness ranging from 7 to 10
microns, and up to 3 mm in length.  

 

Our automated optical inspection stations can only reliably detect
widths of 12 to 15 microns.

 

I've checked the internet in an attempt to find common applications of
this wire.  I've found two, and they were for ultra-fine filters and
stencil screen mesh.  We've investigated (I think) all of our machinery
that would utilize filters this small and have found no such usage.
I've also checked every stencil in our plant, and all of our mesh
material is some type of a plastic compound.

 

Do you have any idea where this stainless steel might be coming from?

 

Any suggestions would be sincerely appreciated!

 

Thanks,

 

Leland


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2