Hi Ioan,
The technical advantages are real—you can solder at much lower peak 
temperatures, because the whole assembly reaches that temperature with significantly 
smaller thermal gradients initially and none at all at solder reflow.
This is in significant contrast to either IR or convection reflow, because in 
both these cases the heat source is at temperatures significantly above what 
your assembly can tolerate—so time is a significant factor and thermal 
gradients as well.
For assemblies with smaller components only, that may not make much of a 
practical difference, but if your assembly is paced by components with larger 
thermal masses, e.g., BGAs, the difference is one of properly wetted solder joints 
everywhere vs. SJs with insufficient heat to properly form in the middle of 
the BGAs, or if properly formed have had the PCB and/or components hot enough 
for serious damage.



Werner
Future workshops:
Reliability Issues with Lead-Free Soldering Processes, June 17, London
Interconnect Failures and Design for Reliability for PCB PTHs, June 17, 
London
Pb-Free Soldering Processes—Survival, Quality, Reliability, August 18, 
Orlando
Reliability Issues with Lead-Free Soldering Processes, September 22, 
Schaumburg
Failure Mode and Root Cause Analyses Reliability (Fatigue, Brittle Fracture, 
ENIG), September 22, Schaumburg





**************
Wondering what's for Dinner Tonight? Get new twists on family 
favorites at AOL Food.
      
(http://food.aol.com/dinner-tonight?NCID=aolfod00030000000001)

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2