Sounds similar to Foresites C3 tester method, but they incorporate a
quick SIR test based on the old military spec "Y pattern" with the
option for IC of the test solution also. 

Rich K / KEJ

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of [log in to unmask]
Sent: Tuesday, April 15, 2008 7:27 PM
To: [log in to unmask]
Subject: Re: [TN] SV: [TN] Ionic Contamination Question (overall vs spot
reading)

W. G. Wargotz (Bell Labs) reported a method for obtaining spot readings
on  a 
PWA. He glued a small Pyrex tube onto a PWA surface in a point where
problems 
 were noted using a RTV type adhesive. The resulting conductivity cell
was 
filled  with the 75/25 test solution, a probe inserted and the reading
was 
generated. I  think the paper was published in the Proceedings from one
of the IPC 
world  conferences. 
Perhaps someone on staff or Werner can check their reference libraries.


Bill  Kenyon
Global Centre Consulting
3336 Birmingham Drive
Fort Collins, CO  80526
Tel: 970.207.9586   Cell:  970.980.6373




**************It's Tax Time! Get tips, forms and advice on AOL Money & 
Finance.      (http://money.aol.com/tax?NCID=aolcmp00300000002850)

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2