Just a thought. Not every shop has deep gold plating tanks, while most all
shops have gold tab plating capability (edge connectors). Plating the main
body with electroplated hard gold would require deep gold tanks.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Scott Lefebvre
Sent: Thursday, March 27, 2008 9:02 AM
To: [log in to unmask]
Subject: [TN] Gold Flash vs. ENIG Solder finish


I have a FAB house that is recommending we switch from using ENIG for
the main body with electroplated hard gold for the edge fingers to an
alternate finish.  They are recommending Gold Flash *Finish the entire
board with 3-10 micro inches of hard Au over 100-200 micro-inches of Ni
and selectively Au plate fingers with 30-50 micro-inches of hard Au.
They reason they want us to change is it removes the step of removing
the tie-bars on the gold edge fingers.

Would this have an affect with solderability switching to Gold Flash?


Scott


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2