TECHNET Archives

March 2008

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Scott Lefebvre <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Scott Lefebvre <[log in to unmask]>
Date:
Thu, 27 Mar 2008 09:01:41 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (24 lines)
I have a FAB house that is recommending we switch from using ENIG for
the main body with electroplated hard gold for the edge fingers to an
alternate finish.  They are recommending Gold Flash *Finish the entire
board with 3-10 micro inches of hard Au over 100-200 micro-inches of Ni
and selectively Au plate fingers with 30-50 micro-inches of hard Au.
They reason they want us to change is it removes the step of removing
the tie-bars on the gold edge fingers.
 
Would this have an affect with solderability switching to Gold Flash?
 
 
Scott 
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2