Hi Paul,
I do not find grid size as major influence surprising, since it has been
shown both analytically and experimentally, that closely spaced vias support each
other.
However, I have a real problem understanding why PCB delamination should act
as a stress relief for the via barrels. I cannot think of any physical
mechanism that would do this—I would guess that there is something else going on in
addition to or as an underlying cause of both the delaminations and the
increase cyclic life.
How about this: initially, high vapor pressure cause the PCB delamination and
is driven out of the resin matrix resulting in subsequent more benign loading
conditions. That should however also work in favor of the 3x260C
preconditioning.
The results you show—and I assume the thermal cycles are all the same:
Coupons tested "as received" achieve 500 thermal cycles to failure (end of
test).
Coupons precondition 3X230°C (tin/lead assembly simulation) achieve 400
thermal cycles.
Coupons precondition 6X230°C (tin-lead assembly and rework) achieve 300
thermal cycles.
Coupons precondition 3X260°C (lead free assembly) achieve 350 thermal cycles.
Coupons precondition 6X260°C (lead free assembly and rework) achieve 500
thermal cycles,
make perfectly good sense until "Coupons precondition 6X260°C (lead free
assembly and rework) achieve 500 thermal cycles"—that makes no sense whatsoever.
Somewhere in your statement "Once in awhile delamination in a group of
coupons will reduce the cycles to failure by ~50%, but most of the time delamination
produces a false positive result by extending cycles to failure. We
differentiate delamination as either stress relieving or stress focusing in a give PWB
build" is the likely clue to this puzzle.
Werner
**************
Create a Home Theater Like the Pros. Watch the video on AOL
Home.
(http://home.aol.com/diy/home-improvement-eric-stromer?video=15?ncid=aolhom00030000000001)
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|