TECHNET Archives

March 2008

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Anslow, Phillip" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Anslow, Phillip
Date:
Wed, 19 Mar 2008 09:09:06 -0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (47 lines)
LGAs (Land Grid Arrays) are increasingly being offered by major vendors.

All appear to have "proven" that these devices are extremely reliable if
the apps notes and websites are taken as evidence. The latest are
appearing with not just peripheral land patterns but multiple rings of
lands, all the way to full arrays. Some have a large heat slug which is
recommended to have thermal vias into PCB for cooling.

Having searched the TechNet archives and found opposing opinion dated
Jan 2006 from Mr. Stadem and Mr. Werner Engelmaier, both trusted
experts, I have some concerns regarding reliability in high-rel, -50 to
+125degC temp cycle spec environments with >4layer and/or >0.062" thick
PCBs, which seems to be what most of the vendors data is based upon.

Has anything changed?

Is this a way for the vendors to avoid balling devices?

Has anyone run some "independent" qualifications of these types of parts
that they could share summaries of?

Some vendors are recommending solder mask defined pads as on the device
giving 2-to-2.5mils standoff, concerned?

Thanks for your responses in advance,

Phil.

 


********************************************************************
This email and any attachments are confidential to the intended recipient and may also be privileged. If you are not the intended recipient please delete it from your system and notify the sender. You should not copy it or use it for any purpose nor disclose or distribute its contents to any other person. 

MBDA UK Limited, a company registered in England and Wales, registration number 3144919 whose registered office is at Six Hills Way, Stevenage, Hertfordshire, SG1 2DA, England.
********************************************************************

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2