Genny ,

What are you seeing that creeps along the legs: SAC, Ag or Tin? If pure
Silver wets as far as to the contact area, I would be scared, because of the
migration risk. I can't see how it could be pure Silver, but I want to know.
I have seen too many times what humidity, Silver and voltage difference can
cause!

A penny for Genny

Inge

-----Ursprungligt meddelande-----
Från: TechNet [mailto:[log in to unmask]] För Genny Gibbard
Skickat: den 6 februari 2008 21:43
Till: [log in to unmask]
Ämne: [TN] SAC on gold pins

So,...
During assembly, say that you see SAC solder wicking up the pins of a
finepitch surface mount header onto the contact area which is
gold-plated.  The gold-plated header normally mates with gold socket
connector.  
What would be the reliability issues with SAC solder in contact with the
gold socket?  Does the silver in the solder mitigate any of the
tin-to-gold issues I have been reading about?

Genny

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2