IPC-600-6012 Archives

February 2008

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Franklin Asbell <[log in to unmask]>
Reply To:
(Combined Forum of D-33a and 7-31a Subcommittees)
Date:
Mon, 4 Feb 2008 16:24:27 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (121 lines)
Sure it's covered, under "must meet customer requirements" Read 3.6.2.11,
notice also it says plating/coating thickness and the reference to copper
thickness (post final finish?) in relation to testing of the final, finished
product, does not consider copper thickness and final finish the same.

Yes, I would agree there are instances where a bare copper product would be
provided, but as stated earlier these would be exceptions (I assume).

I believe we need to separate Code C in Table 3-2 and state this is not
final finish criteria unless specified by the customer.

Franklin

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Thomas F
Gardeski
Sent: Monday, February 04, 2008 3:53 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Bare Copper as a Surface Finish

Bare cooper is only supplied as an intermediate for further processing down
the line. I don't think we have to cover it in 6012B.

Thomas F. Gardeski
Global Technical Service Manager
DuPont High Performance Films
480 831 0975 AZ / 740 474 0269 OH
[log in to unmask]


                                                                           
             John Perry                                                    
             <[log in to unmask]                                             
             G>                                                         To 
             Sent by:                  [log in to unmask]                
             IPC-600-6012                                               cc 
             <IPC-600-6012@ipc                                             
             .org>                                                 Subject 
                                       [IPC-600-6012] Bare Copper as a     
                                       Surface Finish                      
             02/04/2008 01:52                                              
             PM                                                            
                                                                           
                                                                           
             Please respond to                                             
             "(Combined Forum                                              
               of D-33a and                                                
                   7-31a                                                   
              Subcommittees)"                                              
             <IPC-600-6012@IPC                                             
                   .ORG>                                                   
                                                                           
                                                                           




Colleagues,



Our IPC-6012B specification provides for bare copper as a final finish
in Table 3-2, Final Finish, Surface Plating and Coating Thickness
Requirements.



The task group is evaluating whether or not this should be removed from
Table 3-2 in the future IPC-6012 Revision C.  Among the concerns with
bare copper are instances of single-sided via protection that provides
for entrapment of chemistries that attack the bare copper in the hole
wall.



If there are those of you out there who use bare copper as a surface
finish, could you provide feedback to IPC as to how it is used in your
applications?



Thanks in advance,



John Perry

Technical Project Manager

IPC

3000 Lakeside Drive # 309S

Bannockburn, IL 60015

[log in to unmask]

1-847-597-2818 (P)

1-847-615-7105 (F)

1-847-615-7100 (Main)



This communication is for use by the intended recipient and contains
information that may be Privileged, confidential or copyrighted under
applicable law. If you are not the intended recipient, you are hereby
formally notified that any use, copying or distribution of this e-mail,
in whole or in part, is strictly prohibited. Please notify the sender by
return e-mail and delete this e-mail from your system. Unless explicitly
and conspicuously designated as "E-Contract Intended", this e-mail does
not constitute a contract offer, a contract amendment, or an acceptance
of a contract offer. This e-mail does not constitute a consent to the
use of sender's contact information for direct marketing purposes or for
transfers of data to third parties.