I’m looking at Table 3-2 of IPC 6012BA1. Under Code C, Through Holes, Class
3, Minimum Wrap.

 

I interpret this to mean the copper extending from the hole wall wrapping
onto the surface (forming the annual ring) shall be a minimum of ½ mil (472
uin) for a distance of 1 mil (984 uin) from the hole edge.

 

This ½ mil is not including the foil or additional plating (i.e. capping the
via).

 

Am I reading this correctly?

 