Joe, 
 
Having been a part of the committee that worked on 6016, I am sure the  issue 
of remaining foil thickness ever came up.  Quarter ounce, and thinner  foils 
were not envisioned during the late 90's.  Couple of processing  points to 
remember - 
 
1. Will  you have enough copper cross section to carry the current you  
intend to put through the conductor?
 
2. The step after via drill and "laser ash removal" is  metallization.  That 
step, either electroless copper or direct  metallization, will include a 
microetch step to remove copper, you must have  enough copper left to allow that - 
usually less than 0.1 mil or 2.5  microns.  Half ounce foil, as pointed out 
below is 17 microns or quarter  ounce is 9 microns - should be enough to allow 
microetch.  
 
3. You did mention "foil", so I assume you are not trying to build up from  
some additive or semi-additive copper feature from an embedded device like a  
capacitor or resistor. 
 
Denny Fritz
MacDermid, Inc
In a message dated 12/5/2007 7:30:10 A.M. Eastern Standard Time,  
[log in to unmask] writes:

Joe;

From a laser drilling standpoint, we prefer to use a  minimum of half
ounce copper for capture pad foil thickness. We have laser  drilled a few
parts with quarter ounce capture pad foil, but it is tricky  to do so as
the thin coppers buckle and damage easily from the localized  heat of a
laser beam. We have also produced blind vias on plated up sub  assemblies
that start with half ounce foil. We also routinely laser drill  boards
for power management devices that utilize one and two ounce  copper
foils. The thick foils are really hard to damage. 

Dave  Simonik
Laser Process Technician
Sanmina SCI Corp.
Owego NY  Division

-----Original Message-----
From: TechNet  [mailto:[log in to unmask]] On Behalf Of Kane, Joseph E (US
SSA)
Sent:  Tuesday, December 04, 2007 11:54 AM
To: [log in to unmask]
Subject: Blind  Via Question

For HDI vias, what minimum target pad foil thickness is  allowed after 
hole preparation, prior to deposition and copper  plating?  IPC-6016 
does not provide any requirements similar to those  in 
IPC-6012 Table 3-7 for HDI applications.

Joe Kane
BAE  Systems
Johnson City, NY







**************************************Check out AOL's list of 2007's hottest 
products.
(http://money.aol.com/special/hot-products-2007?NCID=aoltop00030000000001)

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2