concur. that being said, the frequency and signal integrity requirements
of the app may not tolerate the additional inductance of a staggered uVia.
At 06:20 AM 12/13/2007, Paul Reid wrote:
>Hi Mark,
>
>Given that you have a well fabricated microvias...
>
>We have found that staggered microvia out perform stacked microvias all
>things being equal (which they never are). Also buried vias filled with
>the flow from the "b stage" material out perform other fills generally.
>
>As for reliability, the best thing to do is test them. We feel robust
>microvias should not fail tested to 190°C in 500 cycles. Most microvia
>will survive 1000 cycles and after that testing becomes a bit academic.
>
>CTE is only part of the story. My sense is that the gradual loss of
>elasticity as a material changes from elastic to plastic due thermal
>cycling is as important. An elastic material relieves stress between
>thermal cycles while a most dielectric materials loses elasticity and
>becomes more plastic causing an accumulation stress between thermal
>cycles. With this in mind, is this a lead free application?
>
>Paul
>
>PWB Inc.
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Mark F. Focht
>Sent: Wednesday, December 12, 2007 7:37 AM
>To: [log in to unmask]
>Subject: [TN] Stacked Via Help
>
>I have a design that,due to space constraints, requires stacking microvias
>(L1-
>L2) directly on top of (in line with) drilled buried vias (L2-L7,
>L2-L11). I am receiving conflicting information about this strategy being
>reliable (storage temp. range -50C to 110C, operating temp. range -40C to
>85C) because of the different CTE's of the via fill material used in the
>L2-L7/L2-L11 vias and the board material (FR406, 170Tg). While the board
>shops that will fab this admit they prefer the vias be staggered (not very
>pratical in this design), they claim they have produced boards of this
>type without negative feedback or issues. The CM that will be assembling
>this is extremely hesitant about using this via strategy. Does anyone
>have experience using a stack-up similar to this? Would this be
>reliable? Is there a plugging paste material that very closely matches
>the CTE of FR406, 170Tg? Any and all comments are welcome.
>
>Thanks,
>
>Mark Focht C.I.D.+
>Pole/Zero Corporation
>5530 Union Centre Dr.
>West Chester, Oh 45069-4821
>
>Voice: 513.870.9060 X173
>FAX: 513.870.9064
>Email: [log in to unmask]
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
>unsubscribe, send a message to [log in to unmask] with following text in the
>BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
>(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
>Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts:
>send e-mail to [log in to unmask]: SET Technet Digest Search the archives of
>previous posts at: http://listserv.ipc.org/archives Please visit IPC web
>site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
>ext.2815
>-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|