A priori, this would seem to be a solder mask problem, but it is not
possible to give you a cause. Some of the possibles are (non exhaustive):
1. Poor curing of the mask
2. Non-stoichiometry of the mask
3. Non-homogeneity of the mask
4. Mask past sell-by date
5. Mask applied over hygroscopic contaminant
6. Hydrogen bonding between flux component and mask
7. Inadequate cleaning
Now, many of these are inter-related (e.g., 6. requires one of 1. to
4.). Whatever, except for 7., you need to intervene at a PCB Fab level.
Brian
Charlie Pitarys wrote:
> I know this has been brought up several times. Searched the archives but
> more help will be appreciated.
> Full process:
>
> Before Reflow PCB have Temperature storage at 65°C for a minimun of 24H
> (some time few weeks)
>
> After Refow before wave solder the PCB have Temperature storage at 70°C
> for 8 hours (the night)
>
> After Wave solder (Pacific 9000M flux) 100% of production is cleaned. Current
> wash temp. was set at 70C. Yes I know this is extreme and advised to
> lower<60C. This helped a little.
> If a sample section PCB is protected with Kapton and Kapton removed before
> cleaning No Problem appears on that solder mask area.
>
> You can even see an outline where the wave solder fingers caused shadowing
> of the solder mask and on the top side along the edge where some flux has
> wicked over.
>
> I need to direct my customer to documents, etc. that have substance on this
> issue. He is hesitant to receive my advise and reasons that I know for this
> occurance. Bad solder mask.
> The problem of white mark is only on few case (less than 5% of PCB).
>
> The PCB I saw was subjected, before any process a Temperature storage of
> 65°C during 3 weeks (can this make the PCB more sensitive ?)
> My flux analysis shows the spectrum has all the signature features for a
> carboxylic acid and a library search brought up adipic acid as the closest
> match.
> Thanks in advance
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|