TECHNET Archives

November 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Ian Hanna <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Ian Hanna <[log in to unmask]>
Date:
Fri, 2 Nov 2007 10:52:31 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (173 lines)
Yet in that same amendment 1 is states;

 D.4.3.1 Group A testing.  Group A testing should be performed to the
specific revision, and amendment if applicable, called out by the
acquisition documents.  For example, if printed wiring boards are
produced to MIL-P-55110D with amendment 1, MIL-P-55110D with amendment
3, and MIL-P-55110E, a manufacturer would be expected to perform group A
testing, for the applicable lot, to the requirements of the revision
specified.

So yes, there is nothing sacred about 55110, except what it says...

You would need to find the old specs to test to if they were called out
on the master drawing.  Even to meet the new and improved spec...



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Franklin D Asbell
Sent: Friday, November 02, 2007 9:12 AM
To: [log in to unmask]
Subject: Re: [TN] MIL-P-55110D Amendment3

Read section 6.4.3 of MIL-PRF-55110.

It states "6.4.3 References on master drawings. All the requirements of
this
specification can be interchangeable with those specifications
identified as
MIL-P-55110. Therefore, existing master drawings or OEM documents
referencing MIL-P-55110 need not be revised, updated, or changed to make
reference to MIL-PRF-55110 in order for this specification to be used."

The problem with maintaining inspection processes which comply with
every
revision of 55110 is due to; 1) most users of 55110 are unaware of this
allowance, 2) they fail to adequately communicate it to their customers.

Revision changes are a fact of life, there is nothing sacred about 55110
making it immune from using the latest revision.

Franklin D Asbell

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ian Hanna
Sent: Friday, November 02, 2007 7:34 AM
To: [log in to unmask]
Subject: Re: [TN] MIL-P-55110D Amendment3

They are probably working from a 15 year-old print -- getting the
authorization to change the print would be next to impossible...and the
parts must meet print -- simple huh?


 
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of - bogert
Sent: Friday, November 02, 2007 4:40 AM
To: [log in to unmask]
Subject: Re: [TN] MIL-P-55110D Amendment3

Why don't you ask your customer if you can work to the latest
MIL-PRF-31032 
which supersedes MIL-P-55110 and MIL-PRF-55110?


>From: Paul P Greene <[log in to unmask]>
>Reply-To: TechNet E-Mail Forum <[log in to unmask]>,              Paul P 
>Greene <[log in to unmask]>
>To: [log in to unmask]
>Subject: [TN] MIL-P-55110D Amendment3
>Date: Tue, 30 Oct 2007 15:13:26 -0500
>
>Hi All,
>         I have a requirement to get the subject specification
(including 
>the
>correct amendment) as we have to certify to it for a customer. The
product 
>is
>old and to be compliant with the drawings we must certify to this. I
have 
>tried
>DSCC and all the associated specification search sites and cannot get
back 
>to
>RevD. I managed to get a copy of RevD with ammendment 4 but need it
with
>amendment 3. I searched the archives and found plenty of correspondance
>but no details of availability.
>Thanks
>Paul
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text
in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at:
http://listserv.ipc.org/archives
>Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach Sasamori at [log in to unmask]
or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2