At 07:24 AM 11/17/2007, Paul Reid wrote:
>Hi Victor,
>
>We see a lot of "hole wall pull away" (HWPA) in RoHS applications, and I 
>agree with Werner's statement, but would like to add one more 
>consideration; out gassing. Recently some "high end" materials have been 
>producing catastrophic HWPA to the degree that internal interconnect are 
>broken.

gee, Paul -- wonder if you have a particular app of ours in mind.  L0L!

On related note, we've observed that some of the higher temp "Pb-free" 
laminates are more resistant to traditional hole prep (i.e. permanganate, 
plasma).  Take the time to look at hole wall roughness after prep (i.e SEM) 
when you're evaluating a new laminate.

We've observed some plasma recipes actually "polish" some FR4 Pb-free 
laminates and make the HWPA worse.  A hybrid stackup was used on the 
product so some plasma was needed to  prep the ptfe laminate to accept 
plating. Permanganate wasn't getting it done in that case so plasma was 
eval'd (alone and in combo w/ permanganate). After that particular plasma 
process, no amount of permanganate processing would roughen the 
surface.  The plasma would polish away any roughening when preceded by 
permanganate.   There were other issues w/ drill profile/smear and quality 
of electroless that had to be improved as well on that project.

Bottomline, don't hesitate to use some tools like SEM to get some a 
qualitative view of hole prep and electroless dep.


>Normal HWPA is considered relatively benign, from a reliability point of 
>view, even stress relieving, but if it causes post separation, well that 
>is not benign.
>
>Sincerely,
>
>Paul Reid
>
>Program Coordinator
>
>PWB Interconnect Solutions Inc.
>235 Stafford Rd., West, Unit 103
>Nepean, Ontario
>Canada, K2H 9C1
>
>613 596 4244 ext. 229
>[log in to unmask] <mailto:[log in to unmask]>
>
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]]On Behalf Of Victor G. Hernandez
>Sent: Wednesday, November 07, 2007 10:04 AM
>To: [log in to unmask]
>Subject: [TN] Post Thermal Stress Hole Wall Pull Away Criteria, cross
>section analysis
>
>
>Fellow TechNetters:
>
>    Where can I find acceptability for PTH quality?
>
>Victor,
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2