Steve,
Good question. 

I found that if I used the plastic coated ones that sometimes if the
plastic sheathing of two wires touched at the wrong time during the
reflow profile one or more of the two touching wires would give screwy
readings - either go to zero or give a reading of 300+C, which of course
is ridiculous. On examination I would find that the plastic was actually
fused together. 

I then switched over to the ones coated with the high temp "cloth" and
have eliminated the problem stated above. I have used these
thermocouples many, many times and have not seen an issue. I have three
to six thermocouples on the samples, so I have a pretty good idea of
what I should be getting.  The agreement is usually less than +/- five
degrees for the sample type I was using.

Bev
RIM

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Tuesday, October 02, 2007 2:04 PM
To: [log in to unmask]
Subject: [TN] Thermocouple Longevity?

Hi Everyone!
 
How many reflow profiles do ya'll put the same thermocouples through
before you think about replacing them?
 
I've typically used them until they quit working or the insulation
deteriorates so bad that I don't want to use them anymore. I was told
that was not a good practice. That your typical K thermocouple starts
drifting after only 4 or 5 thermal cycles. I said; "Really?" I didn't
want to debate a whole lot because it was a customer who said this, so I
just agreed and went on.
 
So, do any of you know this to be a fact, and do any of you trash a
thermocouple after only 4 or 5 profiles and replace them with new ones?
 
Kind regards,
 
Steve Gregory

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2