Hi Everyone!
 
How many reflow profiles do ya'll put the same thermocouples through
before you think about replacing them?
 
I've typically used them until they quit working or the insulation
deteriorates so bad that I don't want to use them anymore. I was told
that was not a good practice. That your typical K thermocouple starts
drifting after only 4 or 5 thermal cycles. I said; "Really?" I didn't
want to debate a whole lot because it was a customer who said this, so I
just agreed and went on.
 
So, do any of you know this to be a fact, and do any of you trash a
thermocouple after only 4 or 5 profiles and replace them with new ones?
 
Kind regards,
 
Steve Gregory

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2