Hi
Why not consider adopting the Military QPL's. Presumably your work
would be largely done.
Monitoring would be your continued responsibility.
Bernie Kessler
At 10:33 AM 10/19/2007, Genny Gibbard wrote:
>Has anyone defined any internal standards for how to approve second
>sources for "generic" components by datasheet review alone, without
>running exhaustive tests on every source?
>I just don't see the point in running 3 weeks of environmental and
>stress tests in order to qualify a $0.002 10Kohm chip resistor second
>source. I should be able to look at a datasheet and say "yes this is
>OK". But when you make OEM products you need to justify why you are
>approving it with this method, and I would like to write up some sort of
>standard to cover off the bases.
>
>I'm looking for places to start. Thoughts?
>
>Thanks as always, and regards,
>Genny.
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
>information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|