Hi Rush,
1) Cracked cu barrels indicate either too thin copper and/or inadequate 
ductility for the thermal expansion experienced;
2) elongation is not a good way of assuring Cu ductility; to get real 
ductility values you need to use IPC-TM-2.4.2.1 or ASTM E-796;
3) you measured thin copper in failed vias;
4) that indicates localized plating conditions were different there than 
coupons—most likely plating current density;
5) QUESTION: Is failure location in same/similar [in terms of copper feature 
density at the surface] sections of PCB?
6) Solution Option #1: Equalize plating current density with thieving 
features.
#2: Plate whole PCB thicker.



Werner



**************************************
 See what's new at http://www.aol.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2