George, Werner,

These are unpopulated brds.
 
YES THERE ARE CPNS ON THE PANEL.(as per IPC-2221)
 
1) CPNS SHOW more than 0.0015" mini in the via holes (in cpns  representing 
via holes)
 
2) However, some assy have failed due to cracked copper.
 
3) 2 assy were X-sectioned and showed low copper ~ 0.001" in the vias that  
cracked. (these are vias in the  brd)...            we do  have pretty good 
plating quality....we check tensile elongation every 2 wks and  elongation always 
runs > 20%.
 
4) We X-secitoned some scrap brds...via plating was fine.
 
5) SO WE feel that, some brds may less plating in these via holes even  
though the cpns show adequate plating.
 
6) HENCE WE WANT TO MEASURE COPPER PLATING IN VIA HOLES (IN A BARE BRD)  
NON_destructively.
 
Rush
818-415-0030
 
 
In a message dated 10/13/2007 4:55:02 PM Pacific Daylight Time,  
[log in to unmask] writes:

I  haven't see your product but just knowing the board i
Hi Rush,

I  haven't see your product but just knowing the board is a 20-layer 150
mils  PCB with a 1.5 mil thick copper requirement for the vias it sounds
like  this isn't a cheap assembly.  I guess that is the reason  you're
looking for a non-destructive measurement.  Unfortunately I  don't think
you are going to find a non-destructive technique for measuring  the
copper thickness in vias on a fully populated PCBA.  Werner's  comment
about a "classic case" is correct.  In fact I would add to his  statement
and say that a non-populated PCB retention sample is always a  good idea
as is non-destructive measurements on bare PCB's prior to  assembly.

Regards,
George
George M. Wenger
Andrew Corporation  Wireless Network Solutions
Senior Principal FMA / Reliability  Engineer
40 Technology Drive, Warren, NJ 07059
(908) 546-4531  [Office]  (732) 309-8964 [Cell]

-----Original  Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner  Engelmaier /*
Sent: Saturday, October 13, 2007 7:30 PM
To:  [log in to unmask]
Subject: Re: [TN] SV: [TN] URGENT HELP NEEDED:-  non-destructive method
for via hole plating thickness

Hi  Rush,
Here is a classic case as to why it is imperative to have coupons  as
part of 
the panel.
you state:
20 layers, ~150 mils  thick
Via holes are 20-22 mils finished; Required plating is 0.0015  min.
Also, for via holes, the finished hole size is totally  unimportant-you
need 
to know the drilled hole size.
Is the required  plating thickness 1.5 mils minimum? or measures how?
You also do not say  whether you have problems, and what the  problems
are.


Werner



**************************************
See  what's new at  http://www.aol.com

---------------------------------------------------
Technet  Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe,  send a message to [log in to unmask] with following text
in
the BODY (NOT  the subject field): SIGNOFF Technet
To temporarily halt or (re-start)  delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or  (MAIL)
To receive ONE mailing per day of all the posts: send e-mail  to
[log in to unmask]: SET Technet Digest
Search the archives of previous  posts at:
http://listserv.ipc.org/archives
Please visit IPC web  site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for  additional
information, or contact Keach Sasamori at [log in to unmask] or  847-615-7100
ext.2815
-----------------------------------------------------

------------------------------------------------------------------------------
------------------
This  message is for the designated recipient only and may
contain privileged,  proprietary, or otherwise private information.  
If you have received  it in error, please notify the sender
immediately and delete the  original.  Any unauthorized use of
this email is  prohibited.
------------------------------------------------------------------------------
------------------
[mf2]


---------------------------------------------------
Technet  Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe,  send a message to [log in to unmask] with following text in
the BODY (NOT the  subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery  of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To  receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]:  SET Technet Digest
Search the archives of previous posts at:  http://listserv.ipc.org/archives
Please visit IPC web site  http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information,  or contact Keach Sasamori at [log in to unmask] or 
847-615-7100  ext.2815
-----------------------------------------------------


 



************************************** See what's new at http://www.aol.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2