Hi Rush,
Here is a classic case as to why it is imperative to have coupons as part of 
the panel.
you state:
20 layers, ~150 mils thick
Via holes are 20-22 mils finished; Required plating is 0.0015 min.
Also, for via holes, the finished hole size is totally unimportant—you need 
to know the drilled hole size.
Is the required plating thickness 1.5 mils minimum? or measures how?
You also do not say whether you have problems, and what the problems are.


Werner



**************************************
 See what's new at http://www.aol.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2