Paymon and Bev et al

We are in the process of an overhaul of SIR in J-STD004 since the  
introduction of 2.6.3.7 in March 07.

Also be aware that HP have instigated their own SIR tests we are all  
trying to take on board.

Whatever tests you are being asked to perform, be very careful with  
the data retrieved.

Kindest regards,

Graham Naisbitt
Co-Chair IPC SIR TG

[log in to unmask]



On 27 Sep 2007, at 16:10, Paymon Sani wrote:

> Bev, this was expected since you are now a grandfather. Time is taking
> its normal course :)
>
> My wife and I had our first born 2 weeks ago but I am feeling sharper
> than before!!!
>
> Regards,
> Paymon
>
>
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: September 27, 2007 10:40 AM
> To: [log in to unmask]
> Subject: Re: [TN] IPC-SF-818, Class III and IPC-TM-650 2.6.3.3 Test
> Methods
>
> Paymon,
> Paymon,
> I must not have taken my happy pill this AM.  In Jack's absence, Tom
> Newton has pointed out to me that I must not be awake this morning.  
> (He
> was more diplomatic than that.)  The version of 2.6.3.3 on the webpage
> (June 2004) is of course NEWER than the version in the old 818 doc  
> (Jan
> 1995). I do not know what I was thinking.
> Bev
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Paymon Sani
> Sent: Thursday, September 27, 2007 9:41 AM
> To: [log in to unmask]
> Subject: Re: [TN] IPC-SF-818, Class III and IPC-TM-650 2.6.3.3 Test
> Methods
>
> Hello Bev,
>
> Thank you for the speedy response, I verified it with our supplier  
> too.
>
>
> Regards,
> Paymon
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: September 27, 2007 8:38 AM
> To: [log in to unmask]
> Subject: Re: [TN] IPC-SF-818, Class III and IPC-TM-650 2.6.3.3 Test
> Methods
>
> Paymon,
> IPC-SF-818 is OLD!  I had to go looking to find my dusty copy of it.
> This is a dead document.  In it at the back it has the IPC-TM-650 Test
> Method 2.6.3.3 of March 1988.  The NEW version, 2.6.3.3, rev B, which
> you can download for free from the IPC webpage, is from, I presume,  
> June
> 2004, since it says 06/04.  I checked other test methods and they show
> the year as the second number.
>
> Interesting!  If I go and look at my hard copy of ANSI/J-STD-004
> (January 1995), at the back of it the copy of 2.6.3.3 is labelled as
> Revision A, yet it has a date of January 1995, which is a newer date
> than the Revision B on the IPC webpage.
>
> Jack!!!!!!!!!!!?
> (Jack is at the IPC meetings this week.  We will probably not hear  
> from
> him until Monday.
> Bev
> RIM
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Paymon Sani
> Sent: Wednesday, September 26, 2007 5:29 PM
> To: [log in to unmask]
> Subject: [TN] IPC-SF-818, Class III and IPC-TM-650 2.6.3.3 Test  
> Methods
>
> Does anyone know the difference between these 2 tests? Our flux
> datasheet refers to the IPC-SF-818, Class III test method for the SIR
> test result but it does not provide the resistance value! Does this  
> test
> method supersede the standard SIR test method as per J-STD-004?
>
>
>
> Thank you in advance,
>
> Paymon
>
>
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------------------------
> This transmission (including any attachments) may contain confidential
> information, privileged material (including material protected by the
> solicitor-client or other applicable privileges), or constitute
> non-public information. Any use of this information by anyone other  
> than
> the intended recipient is prohibited. If you have received this
> transmission in error, please immediately reply to the sender and  
> delete
> this information from your system. Use, dissemination,  
> distribution, or
> reproduction of this transmission by unintended recipients is not
> authorized and may be unlawful.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------------------------
> This transmission (including any attachments) may contain confidential
> information, privileged material (including material protected by the
> solicitor-client or other applicable privileges), or constitute
> non-public information. Any use of this information by anyone other  
> than
> the intended recipient is prohibited. If you have received this
> transmission in error, please immediately reply to the sender and  
> delete
> this information from your system. Use, dissemination,  
> distribution, or
> reproduction of this transmission by unintended recipients is not
> authorized and may be unlawful.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail  
> to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to  
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/ 
> archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp? 
> Pageid=4.3.16 for additional information, or contact Keach Sasamori  
> at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2